Agency-wise Major/critical Ncs at OHT

S.No. Scheme ID Scheme Name OHT Code Non-Compliance Compliance(Current Status)
Description
Major Honey Comb Alignment Cube Test Exposure Deviation Tank Observation Other SBC Issue Demolish Partially Demolish Fully Under Examination Serious Observation Water Body Compliance Major Honey Comb Compliance Alignment Compliance Cube Test Compliance Exposure Compliance Deviation Compliance Tank Compliance Other Compliance SBC Issue Compliance Demolish Partially Compliance Demolish Fully Compliance Under Examination Compliance Serious Observation Compliance Water Body
1 8359217 AHMADPUR DEWARIYA TUBEWELL P2FBD122 No No No No No No No No No No No No No Resolved Tank not placed at the centre of ring beam & not in plumb.
2 8359212 ALUPUR IKDARIYA W/S SCHEME P2FBD121 No No No No No No No No No No No No No Resolved Rusted nut bolt, Tank not placed at the centre of ring beam.
3 8359203 BIDAIL W/S SCHEME P2FBD120 No No No No No No No No No No No No No Resolved Improper drilling in hold down bracket, rusted nut bolt & Tank not placed at the centre of ring beam.
4 20019920 Karamchand Pur W/S Scheme P2FBD134 No No No No No No No No No No No No No Resolved Tank not placed centre of ring beam and hold down bracket not vertically.
5 20019514 Patti Khurd P2FBD22 No No No No No No No No No No No No No Resolved Resolved OHT Column not found in center line.
6 8359330 MUNDGAON W/S SCHEME P2FBD06 No No No No No No No No No No No No No Resolved BBS Not provided before casting 2nd brace beam.
7 20018313 BIBIPUR W/S Scheme P2FBD133 No No No No No No No No No No No No No Resolved Flange nut bolt used where as required washer nut bolt & improper levelling.
8 20016714 Danmandi kamalganj W/S scheme P2FBD132 No No No No No No No No No No No No No Resolved Tank not vertically alignment & used of lower grade nut bolt.
9 20076663 Sultanpur Palnapur & Bhagipur Umrah W/S scheme P2FBD205 No No No No No No No No No No No No No Resolved Flange nut bolt used where as required washer nut bolt & improper levelling & rusted nut bolt.
10 8359185 ISHEPUR W/S SCHEME P2FBD117 No No No No No Yes No No No No No No No Gap Between slab & sheet, Improper centering of ring beam.
11 8359220 NAGARIYA W/S SCHEME P2FBD123 No No No No No Yes No No No No No No No Leakage in bottom of tank & installed corrugated sheet.
12 8359176 UGARPUR SULTANPATTI W/S SCHEME P2FBD114 No No No No No Yes No No No No No No No Installation of DI outlet pipe incorrect way & improper centering of tank on ring beam.
13 20020879 Bhartamau W/S Scheme P2FBD136 No No No No No Yes No No No No No No No Tank not placed centre of ring beam, Improper levelling.
14 20038913 Katrauli Patti w/s scheme P2FBD143 No No No No No Yes No No No No No No No Nut bolt rusted, Tank not placed centre of ring beam.
15 20093607 NAULI SVS P2FBD86 No No No No No Yes No No No No No No No Tank not placed centre of ring beam and hold down bracket not vertically.
16 20019511 Ramapur Dabir W/S Scheme P2FBD56 No No No No No Yes No No No No No No No Honeycombing was found in the OHT second brace beam and the second brace above the first lift column also some places.
17 8359178 RANUKHERA W/S SCHEME P2FBD115 No No No No No Yes No No No No No No No Rusted nut bolt & gap between slab and sheet.
18 20023686 Santoshpur W/S Scheme P2FBD90 No No No No No Yes No No No No No No No Z Truss assembly roof arrangement sheet used in 2.6 mm instead of minimum required 3mm & Tank not vertically.
19 20018367 Allabal Pur W/S Scheme P2FBD18 No No No No No Yes No No No No No No No Hold down bracket not installed vertically, Majority of nut bolt used in assembly Werd found to be rusted.
20 20023193 BEHTA GIPING W/S Scheme P2FBD139 No No No No No Yes No No No No No No No Tank not placed centre of ring beam, Improper levelling.
21 20023823 Daudpur Majra Nandasa P2FBD30 No No No No No Yes No No No No No No No Majority of nut bolt rusted and tank not vertically.
22 20023680 Bhagaura W/S scheme P2FBD71 No No No No No Yes No No No No No No No Flange nut bolt used whereas required washer nut bolt.
23 20023266 Dullamai W/S Scheme P2FBD25 No No No No No Yes No No No No No No No Majority of nut bolt rusted and tank not vertically.
24 20023669 Kutubuddinpur W/S scheme P2FBD70 No No No No No Yes No No No No No No No Flange nut bolt used whereas required washer nut bolt & improper levelling.
25 20023243 Silsanda W/S Scheme P2FBD63 No No No No No Yes No No No No No No No DI pipe load in tank vertically downward.
26 20076280 Kanjhiyana mvs P2FBD147 No No No No No Yes No No No No No No No Improper levelling, Flange nut bolt used whereas required washer nut bolt.
27 8359376 KUNDANGANESHPUR W/S SCHEME P2FBD144 No No No No No Yes No No No No No No No Rusted nut bolts & Improper levelling.
28 20092874 Jhaua MVS P2FBD104 No No No No No No Yes No No No No No No Resolved Excessive rust has developed on the reinforcement in Raft.
29 8388557 DEVRANPUR GADIYA W/S SCHEME P2FBD129 No No No No No No Yes No No No No No No Resolved 7th Flight Staircase Work done Without Raising RFI
30 20023282 Lodhipur W/S Scheme P2FBD182 No No Yes No No No No No No No No No No Resolved Cube fail of OHT bottom slab required Ultrasonic Pulse Velocity.
31 20074354 BAHORA SVS P2FBD167 No No No No No No Yes No No No No No No Resolved concrete pouring in 1st brace beam and found 20 mm aggregate with mixing unapproved materials.
32 20076393 Moosa khiriya w/s scheme P2FBD154 No No No No No No Yes No No No No No No Resolved 10mm aggregate with mixing unwanted material available at site during Raft concrete work.
33 8388559 NAGLA KEWAL WS SCHEME P2FBD208 No No No No No No Yes No No No No No No Resolved Substandard Quality of material are being used in OHT slab
34 8360724 ISHAPUR W/S SCHEME P2FBD127 No No No No No No Yes No No No No No No Resolved This is a serious lapse in site safety and quality control procedures, as proper inspection is essential before concreting.
35 20024456 Hansapur Gouraipur P2FBD188 No No Yes No No No No No No No No No No Resolved Cube fail UPV test TB-3 & Above TB-3 Column.
36 20092660 Sikandarpur Tihaiya MVS P2FBD200 No No Yes No No No No No No No No No No Resolved Cube fail of column above 2nd Brace Beam.
37 20038840 Shadnagar w/s scheme P2FBD191 No No Yes No No No No No No No No No No Resolved Cube fail Slab of Zincalume tank.
38 20092317 Bilsari MVS P2FBD195 No No Yes No No No No No No No No No No Resolved Zi-Al slab (Bilsari ) cube not available in lab during testing required NDT Test.
39 20038943 Faridpur Multi V w/s scheme P2FBD74 No No Yes No No No No No No No No No No Resolved 1st Brace beam cube not available in lab during testing required NDT test.
40 20023298 Nadaura W/S Scheme P2FBD27 Yes No No No No No No No No No No No No Resolved Honeycomb found in 3rd brace beam.
41 20092323 Mahmudpur Achla & Kandhrapur MVS P2FBD148 Yes No No No No No No No No No No No No Resolved Honeycomb Found in column above 1st brace Beam.
42 20023203 Mahmadganj W/S Scheme P2FBD212 No No No No Yes No No No No No No No No Resolved 20mm Extra bar not provided in OHT bottom reinforcement .
43 8359281 BARARIKH W/S SCHEME P2FBD03 Yes No No No No No No No No No No No No Resolved Honeycomb in 2nd brace above 1st lift Column.
44 20023248 Sahab Ganj W/S Scheme P2FBD64 Yes No No No No No No No No No No No No Resolved Honeycomb found 1st lift column.
45 20023856 BHIDAUR W/S SCHEME P2FBD91 Yes No No No No No No No No No No No No Resolved Honeycomb found 1st Brace
46 20023277 Mahrupur Bijal W/S Scheme P2FBD140 Yes No No No No No No No Yes No No No No Resolved Resolved Major Honeycomb in 2nd brace beam.
47 20096551 GADANPURA CHAIN MVS P2FBD94 No No No No No Yes No No No No No No No Hold down bracket not installed vertically & Improper levelling and Tank not vertically align.
48 8359381 PANJU KHIRIYA W/S SCHEME P2FBD126 Yes No No No No No No No Yes No No No No Resolved Resolved Honeycombing was found on the conical wall of the OHT .
49 20038848 Hisampur W/S scheme P2FBD142 No No No Yes No No No No Yes No No No No Resolved Resolved Severe honeycombing and reinforcement exposure noticed at the bottom surface of the 2nd and 3rd brace beams.
50 20023170 Sharfabad W/S Scheme P2FBD138 Yes No No No No No No No Yes No No No No Resolved Resolved Above the 3rd brace at the 2nd lift columns (04 Nos.), honeycombing repair executed using cement paste is unacceptable and has resulted in surface cracking. .
51 20023286 Karhiyoli W/S Scheme P2FBD66 No No No Yes No No No No Yes No No No No Resolved Resolved Honeycombing and reinforcement exposure observed in one of the columns above the 2nd brace level.
52 20023534 Kuiyadhir W/S Scheme P2FBD89 No No No Yes No No No No Yes No No No No Resolved Resolved Major Honeycombing in Brace Beam, Column-Beam junction & Exposed Reinforcement Steel
53 8359188 HAIDARPUR P2FBD118 No No No Yes No No No No Yes No No No No Resolved Resolved A major gap has been observed between the bottom slab ring beam & reinforcement exposure and Major Honeycomb on 3rd Brace Beam.
54 8359324 KHETALPUR SORIYA W/S SCHEME P2FBD176 No No No Yes No No No No Yes No No No No Resolved Resolved Inadequate Concrete Cover in One Colum & Exposuer and Corrosion of Reinforcement, Shear key.
55 20074314 SULTANGANJ KHARETA SVS P2FBD98 No No No No Yes No No No Yes No No No No Resolved Resolved Raft beam casting without RFI & Found beam width 400-420 mm while required 500 mm as pe Approved drawing.
56 20018373 Jiyouna W/S Scheme P2FBD54 No No No No Yes No No No Yes No No No No Resolved Resolved OHT slab, PPC cement was used in the concrete instead of OPC-43 grade cement.
57 20076419 Kuiyan Sant w/s scheme P2FBD110 No No No No Yes No No No Yes No No No No Resolved Resolved Beam width less than Approved drawing.
58 20020108 Usmanganj W/S Scheme P2FBD135 No Yes No No No No No No Yes No No No No Resolved Resolved The staircase was found tilted to one side and Beams (SB1) for the 1st and 2nd staircase landings have been placed along the face of the column instead of at the centerline of the column.
59 20023238 Ambar Pur W/S Scheme P2FBD213 Yes No No No No No No No Yes No No No No Honeycombing was found in the OHT second brace beam and the second brace above the first lift column also some places.
60 20097756 Chachoopur Jatpura MVS P2FBD227 Yes Yes No No No No No No No No No No No Honeycomb 3rd & 4th brace beam, column misaligned above 1st brace.
61 20023290 Antar W/S scheme P2FBD214 No Yes No No Yes No No No No No No No No Dowel bars have not been provided for the staircase reinforcement anchorage, Misaligned column above 3rd brace.