Agency-wise Major/critical Ncs at OHT

S.No. Scheme ID Scheme Name OHT Code Non-Compliance Compliance(Current Status)
Description
Major Honey Comb Alignment Cube Test Exposure Deviation Tank Observation Other SBC Issue Demolish Partially Demolish Fully Under Examination Serious Observation Water Body Compliance Major Honey Comb Compliance Alignment Compliance Cube Test Compliance Exposure Compliance Deviation Compliance Tank Compliance Other Compliance SBC Issue Compliance Demolish Partially Compliance Demolish Fully Compliance Under Examination Compliance Serious Observation Compliance Water Body
1 8361947 FESURA GP 8361947/01 No No No No No No Yes No No No No No No Resolved
2 20096733 Mobarkpur WS 20096733/01 No No No No No No Yes No No No No No No Resolved
3 8388229 Bagahi Kumhapur GOV 8388229/01 No No No No No No Yes No No No No No No Resolved
4 8388188 Bhatija GOV 8388188/01 No No No No Yes No No No No No No No No Resolved
5 20085786 Hinauta urf Jagdishrai WS 20085786/01 No No No No No No Yes No No No No No No Resolved
6 8388252 Kath Kahani GP 8388252/01 No No No No Yes No No No No No No No No Resolved
7 20096731 Duri Kot WS 20096731/01 Yes No Yes No No No No No No No No No No Resolved Resolved
8 8388227 Asana GOV 8388227/01 No No Yes No No No No No No No No No No Resolved
9 8388260 Sawal Jalalpur GOV 8388260/01 No No Yes No No No No No No No No No No Resolved
10 20020154 Chak WS 20020154/01 No No No No No No No No No No No No Yes
11 20020006 Rohakhi WS 20020006/01 No No No No No Yes No No No No No No No The base plate installation is incomplete, as one anchor bolt is missing a nut and the nut on the other anchor bolt has not been properly tightened. Consequently, a gap remains between the base plate and the concrete surface, compromising the structural stability of the assembly. Immediate corrective action is required to ensure proper anchorage and restore structural integrity.
12 8359427 Bhuwalpur GP 8359427/01 No No No No No No Yes No No No No No No Resolved
13 20020487 Karnaul WS 20020487/01 No No No No No No Yes No No No No No No Resolved a critical safety violation was identified on the structural staircase. A large gap exists where a stair tread or landing plate is missing.
14 20020439 Ben WS 20020439/01 No No No No No No Yes No No No No No No A critical safety violation was identified on the structural staircase. A large gap exists where a stair tread or landing plate is missing.
15 8362271 PIPARI GOV 8362271/01 No No No No No No No No No No No No No During site inspection, it was observed that only one landing beam has been provided at the staircase landing, whereas the approved GFC drawing specifies two landing beams. This deviation from the approved drawing may affect the structural behavior and stability of the staircase.
16 8362026 KATWA MAFI GP 8362026/01 No No No No No No No No No No No No No Work on the OHT has been stopped for a long time. Before the work was halted, no protective coating (such as cement slurry or anti-corrosive primer) was applied to the bars, which could lead to damage in the future.